SPATiCOR EN · Scientific Imaging Edition · V30.1 · Gabor / Fourier / Poincaré

Validación interobservador · óvalo de referencia
Óvalo 500 × 300 µmAbre una OCT, calibra X/Y en µm y crea el óvalo. Arrastra su interior para posicionarlo y luego bloquéalo.Cobertura: — · mínimo 60 % · ninguna selección puede salir del óvalo.
La guía es una superposición: no modifica los píxeles originales. Guarda un JSON por imagen B/C/D y entrégalo a ambos observadores con la OCT original correspondiente. La posición y calibración se recuperan exactamente; la ROI de cada observador es independiente.
Calibration · X: — · Y: —
Distance:Unit:X: — · Y: —When enabled, calibrating either axis sets the other axis to the same µm/px value. Verify the image has square pixels.
Research · 3 anatomical ROIs · cumulative dataset
Create three standardized anatomical ROIs. Calibrate X/Y, select the region, and adjust position, height and angle. Drag the anterior ROI horizontally to move the three ROIs together. Each ROI can be fine-tuned independently.
Enter a pseudonymous ID, eye and scan ID. Calibrate the image, place each ROI, then save all three.
PatientEyeScanRegionMeanSDPixel countQualityAction
Do not enter names, medical record numbers or birth dates. Data are held in memory until exported; download your CSV before closing. Right/left refer to image orientation, not nasal/temporal. Gray values are relative to the exported OCT image.
V18.5 · Mapa de 6 ROI · centro y periferia
Carga un OCT y calibra X/Y. Después crea las seis ROI; activa Mover ROI para arrastrarlas individualmente. Las ROI pueden superponerse.
Six ROIs from one scan are correlated regions, not independent samples.
Rectangle settings
RectangleCalibrate X and Y to use physical dimensions. Drag inside the ROI to reposition it.
ROI: none selected
Spatial texture and axial profile
Analyze the active ROI or one of the three anatomical ROIs. Shannon entropy and symmetric, normalized GLCM are computed from original PNG grayscale intensities without image filtering. The axial profile shows mean row intensity versus depth, not a physical optical attenuation coefficient. Calibrate Y for physical depth.
No analysis yet · Select Analyze ROI to open the floating statistics and graph windows.
GLCM simétrica, normalizada, con direcciones 0°, 45°, 90° y 135°; métricas promediadas entre direcciones válidas. La pendiente es regresión lineal de Gray Value por profundidad, sensible a brillo, sombra, ruido, procesamiento y posición de la ROI. Las métricas no constituyen diagnóstico clínico.
Gabor + Fourier 2D
Open an OCT, select a ROI, then analyze. Calibrate X/Y to report periods in µm.
Gabor response · orientation × period
Fourier 2D · log power spectrum
Gabor · directional texture
—

Gabor · response by direction

Detailed 12-value matrix
Fourier · spatial frequencies

Relative power by spatial frequency

Original 2D power spectrum
Poincaré · Persistent topology (experimental)
Select an active ROI, then press Poincaré.

Persistence diagram · Birth vs death (gray value)

Betti curves and methodological notes

Superlevel filtration of native grayscale pixels: bright structures enter at high thresholds. β₀ uses 4-neighbor connectivity. β₁ is computed with the complementary 8-neighbor background; a hole is a dark region not connected to the ROI exterior. A hole's birth/death thresholds are reversed from the complementary background filtration. Pairs touching the filtration endpoints and zero-length pairs are excluded from the persistence diagram. These are topological properties of image intensity, not identified anatomical cysts. ROI boundaries and pixel sampling may alter results.

Spatial texture · Statistics
StatusNot analyzed
Axial profile · Intensity and pixel count
Open an OCT image, pan or zoom, then calibrate.
Zoom: —

Needle-profile analysis · Gray value by depth

Selected depth—
Gray value at depth (0–255)—
Interval mean gray value—
Interval minimum / maximum—
Interval start → end gray value—
Linear slope (gray value / µm)—
Depth is measured along the drawn line from its first endpoint, not automatically perpendicular to the corneal surface. Intensity is relative to the original image (0–255); no smoothing is applied to exported raw samples. Select a depth or interval to add markers to the graph. The interval slope is descriptive, not a physical attenuation coefficient.
OCT statistics · drag to move
Length
—
Mean gray value
—
SD
—
Min / Max
—
ROI size (px)
—
Cross-sectional area
—
Perimeter
—
P90 / P95
—
ROI pixels
—
Pixels ≥ threshold
—
Hyperreflective fraction
—
Area ≥ threshold
—
Mean ≥ threshold
—
OCT graph · drag to move
Research software for corneal OCT image analysis. Gray values are relative to the source image (0–255) and are not a standalone clinical diagnosis. Thresholded area is a two-dimensional cross-section, not a volume. Avoid printed labels, scale bars and charts within the ROI. Compare scans acquired and exported with equivalent settings. All measurements use native image pixels; zoom changes only the display. Physical area requires verified X/Y pixel spacing. Linked-axis calibration is appropriate only when the exported image has square physical pixels.